blob: a3eb154c32caf9f273c8801811565722a3201e38 [file] [log] [blame]
Binding for Cadence UART Controller
Required properties:
- compatible : should be "cdns,uart-r1p8", or "xlnx,xuartps"
- reg: Should contain UART controller registers location and length.
- interrupts: Should contain UART controller interrupts.
- clocks: Must contain phandles to the UART clocks
See ../clocks/clock-bindings.txt for details.
- clock-names: Tuple to identify input clocks, must contain "uart_clk" and "pclk"
See ../clocks/clock-bindings.txt for details.
Example:
uart@e0000000 {
compatible = "cdns,uart-r1p8";
clocks = <&clkc 23>, <&clkc 40>;
clock-names = "uart_clk", "pclk";
reg = <0xE0000000 0x1000>;
interrupts = <0 27 4>;
};