| BlueZ D-Bus Attribute API description |
| ************************************* |
| |
| Copyright (C) 2004-2010 Marcel Holtmann <marcel@holtmann.org> |
| |
| Service details |
| --------------- |
| |
| All characteristics are presented as object paths in a single, flat list. Each |
| object has a "ServiceUUID" property which contains the 128-bit UUID of the |
| service that contains it, so clients can identify the correct characteristic if |
| multiple services contain the same characteristic. |
| |
| This API is used for both local (added to the BlueZ GATT server) and remote |
| (found by GATT discovery) services. |
| |
| Device Characteristic hierarchy |
| =============================== |
| |
| Service org.bluez |
| Interface org.bluez.Characteristic |
| Object path freely definable |
| |
| For local characteristics, it is recommended (for readability and debugging |
| purposes) to have the object path prefix as "[freely definable]/[busid]" where |
| "[busid]" is the application's D-Bus address. For remote characteristics, the |
| device address is added to the prefix. E.g.: |
| |
| [freely definable]/[busid]/characteristic_1803_2A06 (local) |
| [freely definable]/dev_XX_XX_XX_XX_XX_XX/characteristic_1803_2A06 (remote) |
| |
| Methods void SetValue(array{byte} value) |
| |
| Update characteristic value. |
| |
| For a remote characteristic, this method triggers a |
| GATT characteristic value write procedure setting a new |
| value for this characteristic. The GATT sub-procedure |
| is automatically selected based on the characteristic |
| properties and value length. |
| |
| dict GetValue() |
| |
| Read characteristic value and descriptors. The returned |
| dictionary has the following format: |
| |
| { |
| "value": array{byte}, |
| "formatted value": string, |
| // Optional descriptors |
| "client configuration": uint16, |
| "server configuration": uint16, |
| "extended properties": uint16, |
| "user description": string, |
| // For unknown descriptors, use 128-bit UUID |
| // as key |
| "uuid": array{byte}, |
| } |
| |
| Properties string UUID [readonly] |
| |
| 128-bit UUID of this characteristic. |
| |
| string ServiceUUID [readonly] |
| |
| 128-bit UUID of the service which includes this |
| characteristic. |
| |
| boolean Read [readonly] |
| |
| Characteristic value can be read. |
| |
| boolean WriteWithoutResponse [readonly] |
| |
| Characteristic value can be written using GATT Write |
| Without Response sub-procedure. |
| |
| boolean Write [readonly] |
| |
| Characteristic value can be written using GATT Write |
| Characteristic Value sub-procedures. |
| |
| boolean Notify [readonly] |
| |
| Characteristic value can be notified. |
| |
| boolean Indicate [readonly] |
| |
| Characteristic value can be indicated. |
| |
| boolean AuthenticatedSignedWrites [readonly] |
| |
| Characteristic value can be written using GATT Signed |
| Write Without Response sub-procedure. |
| |
| boolean ExtendedProperties [readonly] |
| |
| Characteristic contains additional properties defined |
| on the Extended Properties descriptor. |
| |
| Characteristic Watcher hierarchy |
| =============================== |
| |
| Service unique name |
| Interface org.bluez.Watcher |
| Object path freely definable |
| |
| Methods void ValueChanged(object characteristic, dict value) |
| |
| The value dictionary contains the new value for the |
| Characteristic. The format is the same returned by |
| Characteristic.GetValue(). |
| |
| This method is only called when the "raw" setting is |
| disabled on Adapter.RegisterCharacteristicsWatcher(). |
| |
| void RawValueChanged(object characteristic, array{byte} value) |
| |
| New raw Characteristic value. |
| |
| This method is only called when the "raw" setting is |