| What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_switch_en |
| KernelVersion: 3.0.0 |
| Contact: linux-iio@vger.kernel.org |
| Description: |
| Writing 1 enables the cell balance output switch corresponding |
| to input Y. Writing 0 disables it. If the inY-inZ_balance_timer |
| is set to a none zero value, the corresponding switch will |
| enable for the programmed amount of time, before it |
| automatically disables. |
| |
| What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_timer |
| KernelVersion: 3.0.0 |
| Contact: linux-iio@vger.kernel.org |
| Description: |
| The inY-inZ_balance_timer file allows the user to program |
| individual times for each cell balance output. The AD7280A |
| allows the user to set the timer to a value from 0 minutes to |
| 36.9 minutes. The resolution of the timer is 71.5 sec. |
| The value written is the on-time in milliseconds. When the |
| timer value is set 0, the timer is disabled. The cell balance |
| outputs are controlled only by inY-inZ_balance_switch_en. |