| Introduction |
| ============ |
| |
| This file describes the bnx2x Linux driver for the Broadcom NetXtreme II |
| BCM57710/BCM57711/BCM57711E/BCM57712/BCM57712_MF/BCM57800/BCM57800_MF/BCM57810/ |
| BCM57810_MF/BCM57840/BCM57840_MF 10Gb PCIE Ethernet Network Controllers and |
| Broadcom NetXtreme II BCM57840 10Gb/20Gb PCIE Ethernet Network Controllers. |
| |
| |
| Limitations |
| =========== |
| |
| The current version of the driver has been tested on 2.6.x kernels starting |
| from 2.6.9. The driver may not compile on kernels older than 2.6.9. Testing |
| is concentrated on i386 and x86_64 architectures. Only limited testing has |
| been done on some other architectures. |
| |
| Minor changes to some source files and Makefile may be needed on some |
| kernels. |
| |
| IP Forwarding (bridging) cannot be used with TPA on kernels older than |
| 2.6.26. Please disable TPA with either ethtool (if available) or driver |
| parameter (see "Driver Parameters" section below) |
| |
| The driver makes use of virtual memory for DMA operations. Normally, the |
| driver requires virtual memory of size 8264 kB per physical function at the |
| probe stage. At the open stage, on kernels older than 2.6.16, the driver |
| requires 384 kB of virtual memory per physical function, and on kernels |
| from 2.6.16 and above, the driver requires more 256 kB of virtual memory |
| per physical function. On architectures that the default vmalloc size is |
| relatively small and not sufficient to load many interfaces, use |
| vmalloc=<size> during boot to increase the size. |
| |
| |
| Driver Dependencies |
| =================== |
| |
| The driver uses library functions in the crc32 and zlib_inflate libraries. |
| On most kernels, these libraries are already built into the kernel. In |
| some cases, it may be necessary to load these library modules before the |
| driver or unresolved symbol errors will appear. Using modprobe will |
| resolve the dependencies automatically. |
| |
| In rare cases where the crc32 and zlib_inflate libraries are not enabled |
| in the kernel, it will be necessary to compile the kernel again with the |
| libraries enabled. |
| |
| The driver uses also library functions in the crc32c library. On new kernels, |
| this library is already built into the kernel. In some old kernels, |
| it may be necessary to load this library module before the driver or |
| unresolved symbol errors will appear. Using modprobe will resolve the |
| dependencies automatically. |
| |
| On systems where GRO feature is available, driver uses functions from 8021q |
| library. In some kernels this library is already built into the kernel, in |
| others it may be necessary to load this library module before the driver or |
| unresolved symbol errors will appear. Using modprobe will resolve the |
| dependencies automatically. |
| |
| Driver Settings |
| =============== |
| |
| The bnx2x driver settings can be queried and changed using ethtool. The |
| latest ethtool can be downloaded from http://sourceforge.net/projects/gkernel |
| if it is not already installed. The following are some common examples on how |
| to use ethtool. See the ethtool man page for more information. ethtool settings |
| do not persist across reboot or module reload. The ethtool commands can be put |
| in a startup script such as /etc/rc.local to preserve the settings across a |
| reboot. On Red Hat distributions, "ethtool -s" parameters can be specified |
| in the ifcfg-ethx scripts using the ETHTOOL_OPTS keyword. The specified |
| ethtool parameters will be set during ifup. Example: |
| /etc/sysconfig/network-scripts/ifcfg-eth0: |
| |
| ETHTOOL_OPTS="wol g speed 100 duplex half autoneg off" |
| |
| Some ethtool examples: |
| |
| 1. Show current speed, duplex, and link status: |
| |
| ethtool eth0 |
| |
| 2. Change speed, duplex, autoneg: |
| |
| Example: 100Mbps half duplex, no autonegotiation: |
| |
| ethtool -s eth0 speed 100 duplex half autoneg off |
| |
| Example: Autonegotiation with full advertisement: |
| |
| ethtool -s eth0 autoneg on |
| |
| Example: Autonegotiation with 100Mbps full duplex advertisement only: |
| |
| ethtool -s eth0 speed 100 duplex full autoneg on |
| |
| 3. Show flow control settings: |
| |
| ethtool -a eth0 |
| |
| 4. Change flow control settings: |
| |
| Example: Turn off flow control |
| |
| ethtool -A eth0 autoneg off rx off tx off |
| |
| Example: Turn flow control autonegotiation on with tx and rx advertisement: |
| |
| ethtool -A eth0 autoneg on rx on tx on |
| |
| Note that this is only valid if speed is set to autonegotiation. |
| |
| 5. Show offload settings: |
| |
| ethtool -k eth0 |
| |
| 6. Change offload settings: |
| |
| Example: Turn off TSO (TCP segmentation offload) |
| |
| ethtool -K eth0 tso off |
| |
| 7. Get statistics: |
| |
| ethtool -S eth0 |
| |
| 8. Perform self-test: |
| |
| ethtool -t eth0 |
| |
| Note that the interface (eth0) must be up to do all tests. |
| |
| 9. See ethtool man page for more options. |
| |
| |
| Driver Parameters |
| ================= |
| |
| Several optional parameters can be supplied as a command line argument |
| to the insmod or modprobe command. These parameters can also be set in |
| modprobe.conf. See the man page for more information. |
| |
| The optional parameter "int_mode" is used to force using an interrupt mode |
| other than MSI-X. By default, the driver will try to enable MSI-X if it is |
| supported by the kernel. In case MSI-X is not attainable, the driver will try |
| to enable MSI if it is supported by the kernel. In case MSI is not attainable, |
| the driver will use legacy INTx mode. In some old kernels, it's impossible to |
| use MSI if device has used MSI-X before and impossible to use MSI-X if device |
| has used MSI before, in these cases system reboot in between is required. |
| |
| Set the "int_mode" parameter to 1 as shown below to force using the legacy |
| INTx mode on all NetXtreme II NICs in the system. |
| |
| insmod bnx2x.ko int_mode=1 |
| |
| or |
| |
| modprobe bnx2x int_mode=1 |
| |
| Set the "int_mode" parameter to 2 as shown below to force using MSI mode |
| on all NetXtreme II NICs in the system. |
| |
| insmod bnx2x.ko int_mode=2 |
| |
| or |
| |
| modprobe bnx2x int_mode=2 |
| |
| |
| The optional parameter "disable_tpa" can be used to disable the |
| Transparent Packet Aggregation (TPA) feature. By default, the driver will |
| aggregate TCP packets, but if a user would like to disable this advanced |
| feature - it can be done. |
| |
| Set the "disable_tpa" parameter to 1 as shown below to disable the TPA |
| feature on all NetXtreme II NICs in the system. |
| |
| insmod bnx2x.ko disable_tpa=1 |
| |
| or |
| |
| modprobe bnx2x disable_tpa=1 |
| |
| Use ethtool (if available) to disable TPA (LRO) for a specific NetXtreme II NIC. |
| |
| The optional parameter pri_map is used to map the skb-priority to a Class Of |
| Service (CoS) in the HW. This 32 bit parameter is evaluated by the driver as 8 |
| values of 4 bits each. Each nibble sets the desired HW queue number for that |
| priority. |
| |
| This parameter is only available in kernels which support mapping skb |
| priorities to traffic classes and traffic classes to transmission queues. This |
| means kernel 2.6.39 or newer. |
| Also: |
| on the 5771x family this feature is unavailable (a single COS services all). |
| on the 57712 family two classes of service are available. |
| on the 578xx family three classes of service are availabe. |
| configuring priorities to unavailable COSs will log an error and default to |
| COS 0. |
| |
| For example, set the pri_map parameter to 0x22221100 to map priority 0 and 1 to |
| CoS 0, map priority 2 and 3 to CoS 1, and map priority 4 to 7 to CoS 2. Another |
| example, set the pri_map parameter to 0x11110000 to map priority 0 to 3 to CoS |
| 0, and map priority 4 to 7 to CoS 1. |
| |
| The optional parameter "dropless_fc" can be used to enable a complementary |
| flow control mechanism on 57711 or 57711E. The default flow control mechanism |
| is to send pause frames when the on chip buffer (BRB) is reaching a certain |
| level of occupancy. This is a performance targeted flow control mechanism. |
| On 57711 or 57711E, one can enable another flow control mechanism to send pause |
| frames in case where one of the host buffers (when in RSS mode) are exhausted. |
| This is a "zero packet drop" targeted flow control mechanism. |
| |
| Set the "dropless_fc" parameter to 1 as shown below to enable the dropless |
| flow control mechanism feature on all 57711 or 57711E NetXtreme II NICs in the |
| system. |
| |
| insmod bnx2x.ko dropless_fc=1 |
| |
| or |
| |
| modprobe bnx2x dropless_fc=1 |
| |
| The optional parameter "autogreeen" can be used to force specific AutoGrEEEN |
| behavior. By default, the driver will use the nvram settings per port, but if |
| the module parameter is set, it can override the nvram settings to force |
| AutoGrEEEN to either active (1) or inactive (2). The default value of 0 to use |
| the nvram settings. |
| |
| There are some more optional parameters that can be supplied as a command line |
| argument to the insmod or modprobe command. These optional parameters are |
| mainly to be used for debug and may be used only by an expert user. |
| |
| The debug optional parameter "poll" can be used for timer based polling. |
| Set the "poll" parameter to the timer polling interval on all NetXtreme |
| II NICs in the system. |
| |
| The debug optional parameter "mrrs" can be used to override the MRRS |
| (Maximum Read Request Size) value of the HW. Set the "mrrs" parameter to |
| the desired value (0..3) for on all NetXtreme II NICs in the system. |
| |
| The debug optional parameter "debug" can be used to set the default |
| msglevel on all NetXtreme II NICs in the system. Use "ethtool -s" to set |
| the msglevel for a specific NetXtreme II NIC. |
| |
| |
| Driver Defaults |
| =============== |
| |
| Speed : Autonegotiation with all speeds advertised |
| |
| Flow control : Autonegotiation with rx and tx advertised |
| |
| MTU : 1500 (range 46 - 9000) |
| |
| Rx Ring size : 4078 (range 0 - 4078) |
| |
| Tx Ring size : 4078 (range (MAX_SKB_FRAGS+4) - 4078) |
| |
| MAX_SKB_FRAGS varies on different kernels and |
| different architectures. On a 2.6 kernel for |
| x86, MAX_SKB_FRAGS is 18. |
| |
| Coalesce rx usecs : 25 (range 0 - 3000) |
| |
| Coalesce tx usecs : 50 (range 0 - 12288) |
| |
| MSI-X : Enabled (if supported by 2.6 kernel) |
| |
| TSO : Enabled |
| |
| WoL : Disabled |
| |
| |
| Unloading and Removing Driver |
| ============================= |
| |
| To unload the driver, do the following: |
| |
| rmmod bnx2x |
| |
| If the driver was installed using rpm, do the following to remove it: |
| |
| rpm -e bnx2x |
| |
| |
| If the driver was installed using make install from the tar file, the driver |
| bnx2x.ko has to be manually deleted from the system. Refer to the section |
| "Installing Source RPM Package" for the location of the installed driver. |
| |
| |
| Driver Messages |
| =============== |
| |
| The following are the most common sample messages that may be logged in the file |
| /var/log/messages. Use dmesg -n <level> to control the level at which messages |
| will appear on the console. Most systems are set to level 6 by default. To see |
| all messages, set the level higher. |
| |
| Driver signon: |
| ------------- |
| |
| Broadcom NetXtreme II 5771x 10Gigabit Ethernet Driver bnx2x 0.40.15 ($DateTime: 2007/11/22 05:32:40 $) |
| |
| |
| NIC detected: |
| ------------ |
| |
| eth0: Broadcom NetXtreme II BCM57710 XGb (A1) PCI-E x8 2.5GHz found at mem e8800000, IRQ 16, node addr 001018360012 |
| |
| |
| MSI-X enabled successfully: |
| -------------------------- |
| |
| bnx2x: eth0: using MSI-X |
| |
| |
| Link up and speed indication: |
| ---------------------------- |
| |
| bnx2x: eth0 NIC Link is Up, 10000 Mbps full duplex, receive & transmit flow control ON |
| |
| |
| Link down indication: |
| -------------------- |
| |
| bnx2x: eth0 NIC Link is Down |
| |
| |
| Dual Media Support |
| ================== |
| A dual media capable system connects two PHYs to a single MAC. These PHYs |
| generally use different media types (for example SFP+ fiber and 10GBase-T |
| twisted pair copper) and the dual media configuration requires that the user |
| select a preference among the two PHYs. Supported preferences include manual |
| selection and PHY priority selection. With manual selection, the user specifies |
| that only one PHY should be configured and use to connect to the network. (For |
| example, use the fiber PHY only, always ignore the copper PHY.) With PHY |
| priority selection, the user specifies that either PHY may be used to connect |
| to the network, but when both PHYs indicate link, the PHY with the higher |
| priority will be used to connect to the network. (For example, with fiber PHY |
| priority, if either the copper PHY or the fiber PHY has link, that PHY will be |
| used to connect to the network. However, if both the fiber and copper PHYs have |
| link, the fiber PHY will be used to connect to the network and the copper PHY |
| will be ignored.) When PHY priority selection is used, the PHY which has been |
| selected for network connectivity is referred to as the active PHY. When PHY |
| manual selection is used, there are no special considerations when running |
| ethtool since only one media type is used by the MAC and ethtool is able to |
| control that media type as expected. However, since ethtool is currently not |
| designed to manage the multiple physical interfaces enabled by Dual Media |
| support, the following limitations will apply when ethtool is used on a system |
| with PHY priority selection enabled: |
| |
| 1. Ethtool can be used to display the current physical media information |
| for the active PHY. |
| 2. Ethtool cannot be used to determine whether PHY manual selection or PHY |
| priority selection is in use. This configuration information is available |
| through system specific utilities provided by the vendor. |
| 3. Ethtool can be used to control the current physical media configuration, |
| but this will force the configuration back to PHY manual selection. |
| 4. When ethtool is used to configure the active PHY, ethtool must be called |
| twice, first to change AWAY from the active PHY, then to change BACK to the |
| active PHY. (For example, if the active PHY is copper, ethtool must be first |
| called to change the active PHY to fiber, forcing PHY manual selection |
| to be enabled, then ethtool must be called again to change the active PHY |
| to copper.) |
| 5. Using ethtool to change from PHY priority selection to PHY manual selection |
| only applies to the current session. When the driver is unloaded/reloaded or |
| the system is rebooted, PHY selection will return to the default value. |
| PHY selection defaults must be set outside of Linux with system specific |
| utilities provided by the vendor. |
| |