Fix Chameleon diags SFP TX bias calculation error Early versions of the digital diagnostic standard (SFF-8472) used a scale factor of 1uA/AD Count for interpreting laser bias current readings. SFF-8472 later changed the scale factor to 2uA/AD Count. I used an old spec when I coded up the diags. Now we verified the SFP we used for Chameleon complies with the latest SFF-8472. So I need to change the formula. Change-Id: I6e323ddd7d80a06a5ddc4ca197a254d36d2a734c